[1] Girgis FG, Marshall JL, Monajem A.The cruciate
ligaments of the knee joint: anatomical,functional and experimental analysis[J].Clin Orthop Relat Res,1975,(106):216-231.
[2] Faschingbauer M, Hambrecht J, Schwer J, et al. Tibial insert design significantly alters knee kinematics
using a single cruciate-retaining total knee implant[J].Bone Jt Open,2024,5(7):592-600.
[3] Castagnini F, Bordini B, Cosentino M, et al. Constraint in complex primary total knee arthroplasty: rotating hinge versus condylar constrained implants[J].Arch Orthop Trauma Surg,2022,142(12):3965-3973.
[4] Walker PS, Blunn GW, Broome DR, et al. A knee simulating machine for performance evaluation of
total knee replacements[J].J Biomech,1997,30(1):83-89.
[5] Crawford DA, Lombardi AV. Ligament balancing and constraint in revision total
knee arthroplasty[J].J Knee Surg,2021,34(13):1382-1387.
[6] Kahlenberg CA, Berube EE, Xiang W, et al. Posterior-stabilized versus mid-level
constraint polyethylene components in total knee arthroplasty[J].Bone Jt Open,2023,4(6):432-441.
[7] Szivek JA, Cutignola L, Volz RG. Tibiofemoral
contact stress and stress distribution evaluation of total knee arthroplasties[J].J Arthroplasty,1995,10(4):480-491.
[8] Heckmann ND, Steck T, Sporer SM. Conforming
polyethylene inserts in total knee arthroplasty: beyond the posterior-stabilized and cruciate-retaining
debate[J].J Am Acad Orthop Surg,2021,29(22):1097-1104.
[9] Morgan-Jones R, Graichen H. Balance and
constraint in revision TKR: a classification for
instability management[J].J Orthop,2021,4(24):19-25.
[10] Andriacchi TP, Galante JO, Fermier RW. The
influence of total knee-replacement design on walking and stair-climbing[J].J Bone Joint Surg Am,1982,64(9):1328-1335.
[11] Digennaro V, Brunello M, Di Martino A, et al. Constraint degree in revision total knee replacement: a registry study on 1432 patients[J].Musculoskelet Surg,2024,108(2):195-200.
[12] Sapountzis N, Alamanda VK, Hidaka C, et al. The role of constraint in revision total knee replacement
for instability: full component revision vs isolated
polyethylene exchange in selected patients[J].Arthroplast Today,2023,21:101134.
[13] US-ASTM.ASTM F1223-20:Standard Test Method for Determination of
Total Knee Replacement Constraint[S].American Society for Testing and Materials (ASTM),2014.
[14] Luger E, Sathasivam S, Walker PS. Inherent
differences in the laxity and stability between the intact knee and total knee
replacements[J].The Knee,1997,4(1):7-14.
[15] Halewood C, Athwal KK, Amis AA. Pre-clinical assessment of total knee replacement anterior-posterior constraint[J].J Biomech,2018,17(73):153-160.
[16] Haider H, Walker PS. Measurements of constraint of total knee replacement[J].J Biomech,2005,38(2):341-348.
[17] Klein R, Serpe L, Kester MA, et al. Rotational constraint in posterior-stabilized total knee prostheses[J].Clin Orthop Relat Res,2003,410:82-89.
[18] Moisan P, Barimani B, Kindi MA, et al. Semiconstrained posterior-stabilized total knee arthroplasty: indications, risks and benefits in primary and revision
surgery[J]. Can J Surg,2023,66(2):103-108.
[19] Douglas DA, Komistek RD. Mobile-bearing total knee arthroplasty: design factors in
minimizing wear[J]. Clin Orthop Relat Res,2006,452:70-77.
[20] Czekaj J, Fary C, Gaillard T, et al. Does low-constraint mobile bearing knee prosthesis give satisfactory results
for severe coronal deformities? A five to twelve year
follow up study[J]. Int Orthop,2017,41(7):1369-1377.
[21] Huang CH, Lu YC, Hsu LI,et al. Effect of
material selection on tibial post stresses in posterior-stabilized knee prosthesis[J].Bone Joint Res,2020,9(11):768-777.
[22] Bartel DL, Bicknell VL, Wright TM. The effect of conformity, thickness, and material on
stresses in ultra-high molecular weight components for total joint replacement[J].J Bone Joint Surg Am,1986,68(7):1041-1051.
[23] Han Wu, Yu Guo, Wei Guo. Effect of carbon-fiber-reinforced polyetheretherketone on stress distribution in a
redesigned tumor-type knee prosthesis: a finite element
analysis[J].Front Bioeng Biotechnol,2023,11:1243936.
[24] Chapman-Sheath P, Cain S, Bruce WJ, et al. Surface
roughness of the proximal and distal bearing surface of mobile bearing total
knee prostheses[J].J Arthroplasty, 2002,17(6):713-717.
[25] Willing R, Kim IY. Design optimization of a total knee replacement for
improved constraint and flexion kinematics[J].J Biomech,2011,44(6):1014-1020.
[26] Flannery M, Jones E , Birkinshaw C. Analysis
of wear and friction of total knee replacements part Ⅱ: Friction and lubrication as a function of wear[J].Wear,2008,265(7-8):1009-1016.
[27] David Nečas, Martin Vrbka, Max Marian, et al. Towards the understanding of lubrication mechanisms in total
knee replacements – Part I: Experimental investigations[J].Tribology International,2021,156:106874.
[28] Liau JJ, Cheng CK, Huang CH, et al. The effect of malalignment on stresses in polyethylene component
of total knee prostheses - a finite element analysis[J].Clin Biomech,2002,17(2):140-146.
|